Simple, robust & reliable, the Automated Fluid Handling System works seamlessly with BWB Flame Photometers.
BWB customers rely on our instrumentation to run all day processing tens or even hundreds of samples. Until now, this operation has been a manual process requiring and operator to introduce each sample. Many organizations seek greater efficiency and automation of their laboratory processes and BWB has the solution. The new Automatic Fluid Handling System (AFHS), offers fast, reliable and effective automation of the flame photometry process.
​
New “Auto Read” Technology is the foundation for automation
The goal of an automated system is to perform tasks accurately, reliably and autonomously without the need for human intervention. By clever software/firmware handling of the input from our multiple channel detectors, stability of readings are analytically determined and no longer a subjective user decision.
​
Printer
This ultra reliable thermal printer sits atop the main flame photometer enclosure for footprint reduction in valuable lab space. The printer is supplied with print stock derived from recycled paper, has a 10 year shelf life and comes with soy based ink as standard.
The dimensions of the unit were also designed to offer compatibility with standard calculator print paper available globally from any high street.
​
Autosampler
The BWB auto sampler is available as an optional extra for all the latest models of the BWB flame photometer.
​
Autodiluter
BWB has introduced a 10:1 and 100:1 auto-diluter for the latest models of the BWB flame photometer.
FEATURES
​
-
BUILT AROUND BWB’S PROPRIETARY “AUTO READ” TECHNOLOGY
-
“IRS” (INTERNAL REFERENCE STANDARD) AVAILABLE
-
COMPATIBLE WITH ALL 2014 BWB FLAME PHOTOMETER MODELS
-
5 USER SELECTABLE TRAY CALIBRATION CORRECTION POINTS
-
USER SELECTABLE DILUTION RATIO
-
PURPOSE BUILT AUTO DILUTER
-
ON DEMAND PRINTING OF KEY ANALYSIS DATA WITH BWB’S INTEGRATED PRINTER
-
A SINGLE SHARED POWER SOURCE FOR THE AUTO SAMPLER AND AUTO DILUTER
-
OTHER DILUTIONS ASIDE FROM THE STANDARD OF 100:1 AND 10:1 ARE AVAILABLE WITH THE SAME AUTO DILUTER. CONTACT US FOR SPECIFIC INFORMATION.
-
UP TO 89 SAMPLES
-
INTERCHANGEABLE SAMPLE TRAY
Automated Fluid Handling Systems
The next generation of automation
Check out the AFHS system in action with the BWB BIO flame photometer
Example - BWB BIO with AFHS Technical Data
AFHS is available with most BWB Flame Photometers
Sample rate
4ml/min
Tubing materials
Translucent PTFE and Tygon®
​
Amount of fluid used per sample
based on dilution ratios,
DR1 – 5ml
DR10 – 0.5ml
DR100 – 0.05ml
Specificity
Na/K/Li = <0.5% to each other when
equal in concentration at <100ppm
Required desk space for Instrument
50cm (H) x 65cm (W) x 63cm (D)
*BIO Flame photometer with BWB Recommended set up positioning. For Safety reasons the Flame photometer requires 1m of unobstructed space above to allow dissipation of heat from the chimney.
Instrument size
BIO Flame Photometer
51cm (H) x 38cm (W) x 41cm (D)
(20in x 14in x 16in)
Auto Diluter
30cm (H) x 30cm (W) x 43cm (D)*
(12in x 12in x 17in)
Auto Sampler
30cm (H) x 18cm (W) x 11cm (D)**
(12in x 7in x 4in)
Shipping
62cm (H) x 55cm (W) x 47cm (D) x 2 boxes
(24in x 22in x 19in)
*Inclusive of Cannula operating arm.
** Excluding Dilution Reservoir.
Weight
BIO Flame Photometer – 15.3kg
Auto Diluter – 3.75kg
Auto Sampler – 6.9kg
Shipping
BIO Flame Photometer – 25kg
AFHS unit – 17kg
Optimal range
Multi-point calibration
Na – 0.2 – 300mmol/l*
K – 0.2 – 200mmol/*
Li – 0.2 – 20mmol/l*
Ca – 1 – 20mmol/l*
*With required Dilution Ratios
Reproducibility
<1% Coefficient of variability for 10 consecutive samples within optimal range.
(After instrument stabilisation).
Limit of detection (LOD) and
limit of quantification (LOQ) displayed
LOD LOQ
Na – 0.0013mmol/l Na – 0.0043mmol/l
K – 0.0005mmol/l K – 0.0013mmol/l
Li – 0.003mmol/l Li – 0.0072mmol/l
Ca – 0.0075mmol/l Ca – 0.025mmol/l
Time to stability
Less than 15 seconds after sample
is introduced into the flame
Single sample time
With Auto Diluter: 130 Seconds including Sample Preparation, Acquisition and flush
​
Without Auto Diluter: 80 Seconds
including Acquisition and flush
​
Amount of samples measured per hour
With Auto Diluter: 25
Without Auto Diluter: 40
​
Ions measured
Serum Na and K or Li and Ca
Urine Na and K or Li and Ca
Dilution reservoir size
2.5L with inbuilt low level control
Optional 5L tank available
​
Amount of samples per
dilution reservoir
2.5L – 120* 5L – 240*
*dependant on idle times between traysand sample
set-ups.
​
Amount of samples per tray
89 with additional interchangeable trays
to speed up sampling time.
Calibration concentrations
URINE
Point 1 Point 2 Point 3
Na 25mmol/l Na 50mmol/l Na 100mmol/l
K 25mmol/l K 50mmol/l K 100mmol/l
Li 2.5mmol/l Li 5mmol/l Li 10mmol/l
Ca 2.5mmol/l Ca 5mmol/l Ca 10mmol/l
​
Point 4 Point 5
Na 200mmol/l Na 300mmol/l
K 150mmol/l K 200mmol/l
Li 15mmol/l Li 20mmol/l
Ca 15mmol/l Ca 20mmol/l
​
SERUM
Point 1 Point 2 Point 3
Na 120mmol/l Na 130mmol/l Na 140mmol/l
K 3mmol/l K 4mmol/l K 5mmol/l
Li 0.5mmol/l Li 0.5mmol/l Li 1mmol/l
Ca 1.5mmol/l Ca 2mmol/l Ca 2.5mmol/l
​
Point 4 Point 5
Na 150mmol/l Na 160mmol/l
K 6mmol/l K 7mmol/l
Li 1.5mmol/l Li 2mmol/l
Ca 3mmol/l Ca 3.5mmol/l
Recommended minimum warm up
time based on ambient temperature
21°C – 40 minutes
Power requirements
100V – 250V AC at 50 or 60Hz
Fuel requirement
Propane, Butane or Natural Gas*
regulated to 19Bar. Flow rate of 0.4l/min
*with modifications. BWB Technologies recommends either Propane or Butane for optimum results.
Readout
LCD, four line, alpha numeric, back lit.
WHAT’S IN THE BOX
​
-
PC Leads USB and RS232
-
Selection of 3 Power cables
to suit all regions -
Gas Hose
-
Aspiration Kit
-
Manuals covering all aspects
of the BIO FP and AFHS -
Quick Start guides
-
Warranty Registration Form
-
Certificates of analysis for all provided Fluids
-
Material Safety Data Sheets for all provided Fluids
-
IQ, OQ, PQ On-line Documentation. Certificate of Compliance will be issued upon completion of the
PQ testing. -
The FP-PC Software installation CD
-
1L of BWB recommended
cleaning solution -
Complete set of calibration fluids including Diluent Concentrate
-
250 x 5ml AFHS screw top
sample Vials -
100ml conical flask with screw lid
-
100 disposable sample cups
-
1L of De-Ionised water
-
2m of waste tube
-
Set of spare fuses
-
10 x 10ml pipettes
-
10 x 1ml pipettes