top of page
AW XP DECAL.png

The BWB XP Flame Photometer

Our award winning 5-channel instrument

Ready to use straight out of the box!

General Purpose Flame Photometer!

 

The BWB XP is the first and only 5 channel flame photometer

with simultaneous detection and display of all 5 elements.

​

The BWB XP was designed from the ground up, using new, innovative and modern technology to give unsurpassed levels of accuracy, usability and reliability while significantly reducing analysis time. Our customers do not need to waste valuable time changing filters and re-calibrating when a different measurement is required, as is a common requirement in all other Flame Photometer designs from 1951 to the present. 

​

With clean lines and contemporary bright colour schemes, the XP looks exceptionally modern and will fit into any laboratory. The instrument has a large LCD display, which can be viewed easily from any angle.

​

Our metal casework provides a sturdy portable instrument and enables future recycling opportunities. ROHS compliant components and materials are used wherever possible.


The BWB Carbon Footprint is exceptionally low, in keeping with corporate objectives of being a responsible manufacturer.

​

Unlike other manufacturers who charge extra for vital accessories, BWB include everything required to use the product straight out of the box. Just add Gas!! (Propane, LPG or butane).

​

We also provide as standard, data sharing via USB from the BWB XP to your PC. This ties the output of the BWB Flame Emission Spectrometer (FES) to the Internet or your company intranet systems and facilitates Distributed Control which is vital for Multi-National companies, Universities and various Governmental agencies.

​

​

The BWB XP is the greatest advance in flame photometry for 30 years!

Main Brochure Graphic 2023.png
Li Tile sm.png
Na Tilesm.png
K Tile sm.png
Ca Tile cmall.png
Ba Tile small.png

FEATURES

​

 

  • SIMULTANEOUS DETECTION AND DISPLAY OF ALL 5 ATOMS OF INTEREST 

 

  • INTUITIVE USER INTERFACE FOR TRUE EASE OF USE 

 

  • DISPLAY PROMPTS STEP BY STEP OPERATION 

 

  • BUILT-IN AIR COMPRESSOR 

 

  • SOLUTIONS AND LABWARE INCLUDED 

 

  • DATA SHARING VIA PC LINK VIA USB
     

  • OPERATOR INDEPENDENT DETERMINATION OF RESULTS 

​

  • 5 USER SELECTABLE UNITS OF MEASURE 

 

  • USER SELECTABLE DECIMAL PLACES 

 

  • INTEGRATED PRINTER OPTION USES READILY AVAILABLE PAPER 

 

  • IQ, OQ, PQ WEB-BASED CERTIFICATION AVAILABLE: IQ OQ PQ is completely unique in the analytical instrumentation arena. Available in English, Russian, German, Mandarin, French and Spanish.More languages in development

​

  • CORRECTION OF CA FOR THE INTERFERENCE FROM HIGH LEVELS
    OF NA

XP CUT-OUT_CMYK_2023.png
Detail3.png

Technical Data

Sample rate 

2 – 3.5ml/min

​

Tubing materials 

Silicone and Tygon®  

​

Required desk space for Instrument  

50cm (H) x 45cm (W) x 45cm (D)*

For Safety reasons the Flame photometer requires 1m of unobstructed space above to allow dissipation of heat from the chimney.

​

Instrument size 

XP Flame Photometer
51cm (H) x 38cm (W) x 41cm (D)
(20in x 14in x 16in)

​

Shipping
62cm (H) x 55cm (W) x 47cm (D)
(24in x 22in x 19in)

​

Weight 

XP Flame Photometer – 15.3kg (33.7lbs)

Shipping – 25kg (55.1 lbs)

​

Optimal range

Single point calibration

Na 0.1 – 60ppm 

K 0.05 – 100ppm 

Li 0.05 – 50ppm 

Ca 1.0 – 100ppm 

Ba 1.6 – 100ppm

​

Multi Point Calibration

Na 0.1 – 1000ppm 

K 0.05 – 1000ppm 

Li 0.05 – 1000ppm 

Ca 1.0 – 1000ppm 

Ba 5.0 – 3000ppm 

​

Reproducibility 

<1% Coefficient of variability for 20 consecutive samples over ten minutes at concentrations of 100ppm or less. (After instrument stabilisation). 

Specificity 

Na/K/Li = <0.5% to each other when equal in concentration at <100ppm

​

Limit of detection (LOD) and
limit of quantification (LOQ) 

LOD                     LOQ        

Na – 0.03ppm    Na – 0.1ppm

K – 0.02ppm      K – 0.05ppm

Li – 0.02ppm     Li – 0.05ppm

Ca – 0.3ppm      Ca – 1ppm

Ba – 1.6ppm      Ba – 5.0ppm

​

Time to stability 

Less than 15 seconds after sample is introduced into the flame.

​

Ions measured  

Simultaneous measurement of Na, K, Li, Ca, Ba

​

Interfaces  

USB

0-2.5 volt output (based on sample concentration linked to element of users choice)

Optional 4-20mA output in place of the above

Optional integrated printer

.csv and .pdf generated reports and files via FP-PC software

​

Recommended minimum warm up time based on ambient temperature  

21ºC – 40 minutes     

​

Power requirements   

100V – 250V AC at 50 or 60Hz automatically selecting 

​

Fuel requirement    

Propane, Butane or Natural Gas* regulated to 19Bar. Flow rate of 0.4l/min

*with modifications. BWB Technologies recommends either Propane or Butane for optimum results.

​

Readout  

LCD, four line, alpha numeric, back lit.

WHAT’S IN THE BOX

​

 

  • PC Leads USB and RS232

  • Selection of 3 Power cables to suit all regions

  • Gas Hose

  • Propane Adapter

  • Aspiration Kit

  • Manuals covering all aspects
    of the XP FP 

  • Quick Start guides 

  • Warranty Registration Form 

  • Certificates of analysis for all
    provided Fluids 

  • Material Safety Data Sheets for all provided Fluids 

  • The FP-PC Software installation USB 

  • 1L of BWB recommended
    cleaning solution 

  • 150ml calibration fluids for all 5 elements at 10,000ppm.

  • 100ml conical flask with screw lid

  • 100 disposable sample cups 

  • 1L of De-Ionised water

  • 2m of waste tube

  • Set of spare fuses

  • 10 x 10ml pipettes 

  • 10 x 1ml pipettes

XP-pack RE-TOUCHED_2019_2023.jpg
bottom of page